Essays /

Lab Report Essay

Essay preview

Table of Contents
Abstract……………………………………………………………………………………………2 Introduction………………………………………………………………………………………..2 Background………………………………………………………………………………..2 Objectives…………………………………………………………………………………2 Scope………………………………………………………………………………………3 Theory review……………………………………………………………………………………..3 Design of report…………………………………………………………………………………...5 Procedures…………………………………………………………………………………………5 Results……………………………………………………………………………………………..6 Discussion…………………………………………………………………………………………6 Conclusion………………………………………………………………………………………...7 Reference……………………………………………………………………………………….....7 Appendix…………………………………………………………………………………………..7

ABSTRACT
This experiment introduces the use of dimensionless analysis and conventionally analytical method to survey the performance of centrifugal pump. The end of this experiment points out the benefit of using the “new” method to the conventional in most practical problem, especially in the survey of turbo-machine. Also, through this experiment, students know some basic indexes to assess the efficiency of pumps used. We will that for the specific fan conducting this experiment, the best efficiency point occurs at CQ = 0.2, the specific speed NS ~1.23. INTRODUCTION

Background
A fan is a turbo-machine in which work is done to increase the total pressure of the fluid leaving the device. This is achieved by a rotor or impeller, which is driven by an external source of power to move a row of blades so as to impart energy to the fluid. A centrifugal fan, the focus of this experiment, consists basically of three components: an air inlet duct, an impeller and a volute casing. The inlet duct conducts the fluid (in this case, it is air) into the impeller. The air then passes through a rotating row of blades resulting in the increase in pressure and velocity. The high velocity of the air in the exit of the impeller is converted into additional pressure rise by velocity reduction in the volute which acts basically as a fluid collection channel. The air at higher pressure is then delivered through the outlet duct and is finally discharged into a chamber or the atmosphere. (About a centrifugal fan and the volute: please see the...

Read more

Keywords

-6 /wiki/volute_(pump) 0 0.1385 0.140 0.144 0.1935 0.1945 0.2 0.25 0.2519 0.2559 0.75 0o 1 1.161 1.169 1.2258 1.23 1.2371 10 100kpa 12 15 1500 18.6 1st 2 2.25 2.692 20 2010 2100 2103 220 27.80 287 2nd 3 30 300k 4 40 5 50 6 7 70 75 758.79 90 90o abstract accur achiev across act actual addit adjust advantag air allow almost also among analysi analyt appendix appli applic appropri approxim assess atmospher attach automat b b.r background backward base basic bench benefit best blade blank buckingham burden c calcul calibr carri case cd centrifug chamber chang channel chapter character characterist charg choos close coeffici coincid collect compar complet compon concept conclud conclus condit conduct consist constant contain content control convent convert cp cp3/4 cq cq1/2 current curv d d.f damper data deduc deeper degre deliv densiti deriv describ design desir determin develop devic diamet differ difficult difficulti dimens dimension dimensionless direct discharg discuss distinct distribut done driven drop duct e.g earlier easili econom economi effect effici en.wikipedia.org en.wikipedia.org/wiki/volute_(pump) enabl end energi equal equat equip especi essenti estim evalu exact excel except exit experi express extern facilit famili fan fig figur file final find flow fluid focus follow formula forward fulfil fulli function fundament furthermor gain gas general geometr give given graph group guess ha hand happen head help henc high higher highest homogen howev ideal illustr imag impart impel impli import increas independ index inform inlet input instead instrument introduc introduct involv j/kg.k k k-r kg/m3 know lab laboratori larg last law leav less limit line locat long m m3/s machin main make manag manomet max maximum may meanwhil measur mechan meter method minimum mmhg model mount move ms muson n/m2 nearest necessari need new non non-dimension normal note ns number object oc occur offer often okiishi one open oper other outlet p pa.s paramet pass patm peak perform pexit physic pinlet pleas plot point posit possibl power practic predict pressur prm problem procedur process product prototyp provid pump q qrpm quantiti quit r rad/s radial rate re read real record reduc reduct refer regim regul relat relationship relev repeat report repres requir respect result review reynold rise rotat rotor row rpm run scale scope second section see set shape show shutoff signific similar similitud size sourc specif speed start still student studi suitabl suppli support survey switch system t.h tabl take talk tatm technician temperatur term test theorem theori therefor three top total tradit turbo turbo-machin two type typic uncondit understand uniqu unit us use usual valu vari variabl veloc venturi view viscos voltag volum volut wiley work write x x105 york young μ π π-theorem ρ ρatm ρg ρrtatm ω ωd3